Replacement content

Commercial Range Inbuilt Economy Cycle /Split Ducted/Rooftop Packaged Air Conditioners
R410a 8kW to 73kW
R407C 80kW to 200kW
Smart Design for Energy Efficiency

More than ever there is a key focus within the HVAC industry on developing smarter design solutions.
Smart designs that assist in reducing green house emissions and achieving significant energy efficiency and power savings.
 
Since heating and cooling are major contributors to peak demand for energy, air conditioning suppliers continue to investigate and implement cost effective design initiatives for the increase of HVAC efficiency.

Dunnair range of Split Ducted & Rooftop Packaged Commercial Air Conditioners with the energy saving feature of inbuilt Economy Cycle, utilises outside air to supplement or replace cooling whenever the ambient air is at an appropriate temperature.

Dunnair Inbuilt Economy Cycle includes dampers, damper motors and filters – Units are fully complete and ready to connect to ductwork.

Dunnair Economy Cycle units are not only an energy efficient solution but a smart design platform of inbuilt motorised dampers and filters which provides a resourceful and cost effective method of onsite unit installation

This design efficiency leads to significant cost savings including:
> Reduced material cost
> Installation time saving
> Labour cost saving
> Finished cost saving

 
Economy Cycle Air Cooled Split Ducted Units (click on model numbers to view/download specifications)

Model Total Cooling
Capacity
(kw)
Sensible Cooling
Capacity
(kw)
Heating
Capacity
(kw)
Nominal
Air Flow
(L/S)
Phase Full
load
Amps
Noise
levels
(dba)
(indoor)
Noise
levels
(dba)
(outdoor)
Refrigerant
Circuits
Fan
Drive

Dimensions
LxWxH (mm)
(Outdoor Unit)

Dimensions
LxWxH (mm)
(Combined FC & Eco cycle)
SHSE6 6.2 5.3 5.9 360 1 14.6 47.8 55.5 1 Direct 860 x 310 x 718 1750 x 1140 x 400
SHSE8 7.8 6.8 7.4 472 1 15.1 46.5 56.4 1 Direct 950 x 340 x 840 1850 x 1390 x 400
SHSE10 9.1 7.9 9.4 560 1 20.1 48.6 56.7 1 Direct 950 x 340 x 840 1850 x 1390 x 400
SHSE12 11.5 9.7 12.1 695 3 11.6 68.4 57.5 1 Direct 950 x 350 x 950 1850 x 350 x 950
SHSE15 14.3 13.0 14.2 850 3 12.1 61.8 58.2 1 Direct 950 x 340 x 1245 1900 x 1690 x 420
SHSE18 17.1 15.1 18.0 1000 3 13.5 63.7 59.8 1 Direct 950 x 340 x 1230 1900 x 1840 x 420
SHSE20 19.9 15.9 19.5 1110 3 16.0 70.5 73.7 1 Direct 950 x 340 x 1230 2000 x 1890 x 420
SHSE25 24.2 19.3 24.5 1390 3 19.3 71.0 74.9 1 Direct 1300 x 950 x 700 2100 x 1990 x 485
SHSE30 30.6 25.4 30.6 1800 3 23.3 69.8 75.5 1 Direct 1300 x 950 x 930 2100 x 2240 x 485
SHSE35 34.8 28.8 32.4 2000 3 25.5 70.3 75.3 1 Direct 1300 x 1000 x 930 2100 x 2440 x 485
SHE40 39.7 32.6 36.1 2200 3 29.2 71.4 75.7 2 Belt 1550 x 1200 x 900 2500 x 1640 x 860
SHE45 44.8 37.6 44.2 2700 3 32.8 72.2 76.2 2 Belt 1550 x 1400 x 900 2550 x 1840 x 860
SHE50 48.6 39.8 44.2 2800 3 38.9 72.8 76.7 2 Belt 1800 x 1755 x 910 2650 x 1940 x 860
SHE56 55.6 45.0 57.4 3000 3 41.7 72.8 77.1 2 Belt 1800 x 1755 x 910 2650 x 1940 x 860
SHE66 65.5 50.9 60.7 3500 3 46.3 73.1 77.7 2 Belt 1800 x 1755 x 910 2800 x 2500 x 920
SHE73 72.8 59.3 66.6 3900 3 51.2 73.7 78.4 2 Belt 1800 x 1755 x 910 2800 x 2500 x 920
SHE80 80.4 65.5 80.7 4300 3 61.4 74.6 79.0 2 Belt 1800 x 1803 x 910 2850 x 2500 x 1020
SHE90 88.5 71.0 85.0 4800 3 72.6 75.5 79.6 2 Belt 1800 x 2080 x 1100 2900 x 2720 x 1050
SHE100 102.2 82.9 98.5 5500 3 91.0 77.3 80.6 2 Belt 2050 x 2050 x 1450 3120 x 2570 x 1450
SHE120 117.6 95.2 116.2 6500 3 98.9 77.1 82.2 2 Belt 2050 x 2050 x 1450 3220 x 2720 x 1550
SHE140 137.8 110.6 132.0 7500 3 125.4 77.7 83.3 2 Belt 2050 x 2050 x 1550 3350 x 3070 x 1550
SHE160 156.2 127.5 152.5 8500 3 140.2 80.1 83.7 2 Belt 2050 x 2050 x 1650 3600 x 3270 x 1550
SHE180 176.8 143.6 169.4 9500 3 170.2 82.5 85.4 2 Belt 2150 x 2150 x 2350 3900 x 3470 x 1650
SHE200 201.8 164.3 196.2 10500 3 190.3 82.2 87.2 2 Belt 2150 x 2150 x 2350 4000 x 3770 x 1650
 
Cooling capacity is based on 27°C DB, 19°C WB Entering Air Temperature & 35°C Ambient Temperature Sound Pressure Levels are from 1 metre of the outdoor unit.
The Manufacturer reserves the right to modify the data in this catalogue without warning.
 
Economy Cycle Air Cooled Rooftop Packaged Units (click on model numbers to view/download specifications)

Model Total Cooling
Capacity
(kw)
Sensible Cooling
Capacity
(kw)
Heating
Capacity
(kw)
Nominal
Air Flow
(L/S)
Phase Full
load
Amps
Noise
levels
(dba)
(indoor)
Refrigerant
Circuits
Fan Drives

Dimensions
LxWxH (mm)
(Outdoor Unit)

Weight
(Kgs)
PHSE8

7.8

7.2

7.6

472

1

15.7

66.8

1

Direct

1840 x 1050 x 810

268

PHSE10

9.1

7.9

9.4

555

1

16.8

67.2

1

Direct

1840 x 1050 x 810

268

PHSE12

11.5

9.7

12.1

695

3

9.5

69.7

1

Direct

1850 x 1150 x 865

300

PHSE15

14.3

13.0

14.2

850

3

11.8

70.6

1

Direct

2100 x 1290 x 865

332

PHSE18

17.1

15.1

18.0

1000

3

13.4

70.4

1

Direct

2100 x 1290 x 865

340

PHSE20

19.9

15.9

19.5

1110

3

15.0

73.5

1

Direct

2140 x 1400 x 860

448

PHSE25

24.2

19.3

24.5

1390

3

19.2

74.9

1

Direct

2350 x 1600 x 1020

520

PHSE30

30.6

25.4

30.6

1800

3

23.2

74.7

1

Direct

2450 x 1800 x 1010

618

PHSE35

34.8

28.8

32.4

2000

3

25.4

75.2

1

Direct

2450 x 1800 x 1010

625

PHE40

39.7

32.6

36.1

2200

3

28.6

75.4

2

Belt

2600 x 1850 x 1345

670

44.8

36.8

44.2

2700

3

32.4

76.3

2

Belt

2810 x 1850 x 1345

680

48.6

39.8

44.2

2800

3

38.9

77.2

2

Belt

3160 x 1900 x 1450

810

55.6

45.0

57.4

3000

3

41.7

77.6

2

Belt

3160 x 1900 x 1450

825

65.5

50.9

60.7

3500

3

46.3

78.2

2

Belt

3290 x 2100 x 1580

915

72.8

59.3

66.6

3900

3

51.2

78.7

2

Belt

3290 x 2130 x 1580

940

80.4

65.5

80.7

4300

3

61.4

78.9

2

Belt

3470 x 2130 x 1580

990

88.5

71.0

85.0

4800

3

72.6

79.9

2

Belt

3550 x 2130 x 1880

1060

102.2

82.9

98.5

5500

3

91.0

81.5

2

Belt

3860 x 2130 x 1900

1250

117.6

95.2

116.2

6500

3

106.0

82.5

2

Belt

4160 x 2130 x 2000

1240

137.8

110.6

132.0

7500

3

125.4

83.8

2

Belt

5700 x 2050 x 2050

2140

156.2

127.5

152.5

8500

3

140.2

86.0

2

Belt

5800 x 2050 x 2050

2180

176.8

143.6

169.4

9500

3

177.3

87.4

2

Belt

5900 x 2100 x 2350

2480

201.8

164.3

196.2

10500

3

190.3

89.4

2

Belt

5900 x 2100 x 2350

2520

Cooling capacity is based on 27°C DB, 19°C WB Entering Air Temperature & 35°C Ambient Temperature Sound Pressure Levels are from 1 metre of the outdoor unit.
The Manufacturer reserves the right to modify the data in this catalogue without warning.
Home | About Us | Dunnair Products | Downloads | Contact Us